EduKG
← Back

Significant figures in physical results

Learning objectives

  • Outcome

    Count the number of significant figures in a given recorded value, including cases of leading, internal, and trailing zeros.

  • Outcome

    Round the result of multiplication and division to the smallest number of significant figures, and the result of addition and subtraction to the smallest number of decimal places.

  • Outcome

    Write a physical result in standard form a×10na\times10^{n} while preserving the required number of significant figures.

Understand the idea

Significant figures in physical results: rules of recording and rounding

Text

Significant figures are the digits in a recorded value that carry information about its accuracy; counting begins at the first non-zero digit on the left. Leading zeros are not significant (0.00450.0045 has two significant figures), internal zeros are significant (1.021.02 has three), and trailing zeros are significant only when a decimal part is present (2.302.30 has three, but 23002300 with no further notation has two). In standard form a×10na\times 10^{n} with 1≤a<101\le a<10, the exponent nn does not affect precision: all digits of the factor aa count. In multiplication and division the result is rounded to the smallest number of significant figures among the inputs, while in addition and subtraction it is rounded to the smallest number of decimal places. Intermediate steps are carried with one or two extra digits and only the final answer is rounded, otherwise rounding error accumulates. Significant-figure rules give a quick estimate of precision; a stricter method is to state the uncertainty directly, for example L=(12.35±0.05)L=(12.35\pm 0.05) cm.

Worked examples

Direct

Problem

Determine the number of significant figures in: (a) 0.0045070.004507 m; (b) 2.30×1042.30\times10^{4} kg; (c) 15001500 m (no decimal part, trailing zeros not specified).

Solution

Step 1. Counting always starts at the first non-zero digit. In (a) the leading zeros 0.000.00 are dropped, then come the digits 44, 55, 00, 77; the zero between 55 and 77 is significant, so (a) has 4 significant figures. Step 2. In (b) the factor is 2.302.30: the trailing zero is significant because a decimal part is present, and the exponent 10410^{4} does not affect precision, hence 3 significant figures. Step 3. In (c), with no decimal part the trailing zeros are normally not significant, so only 11 and 55 count: 2 significant figures. To state four significant figures one would write 1.500×1031.500\times10^{3} m.

Application

Problem

Find the area of a rectangle with sides a=12.35a=12.35 cm and b=4.2b=4.2 cm and write the answer with the correct number of significant figures. Then add 12.3512.35 cm and 0.20.2 cm and round the sum by the addition rule.

Solution

Area (multiplication). Compute S=a⋅b=12.35⋅4.2=51.87S=a\cdot b=12.35\cdot 4.2=51.87 cm$^{2}$. The smallest number of significant figures in the data is two (from b=4.2b=4.2 cm), so round to two digits: S=52S=52 cm$^{2}$. Sum (addition). Add: 12.35+0.2=12.5512.35+0.2=12.55 cm. Here the rule differs: look at the number of decimal places and take the smallest — 0.20.2 cm has one decimal place, so round the answer to tenths: 12.612.6 cm. Conclusion. These are two different numbers, each rounded by its own rule: the product 51.8751.87 rounds to 5252 (two significant figures, multiplication/division rule), and the sum 12.5512.55 rounds to 12.612.6 (one decimal place, addition/subtraction rule).

Transfer

Problem

The density of a metal is determined as follows: mass m=24.31m=24.31 g (four significant figures), volume by displacement with initial level V1=50.0V_{1}=50.0 mL and final level V2=58.5V_{2}=58.5 mL. Compute ρ=m/(V2−V1)\rho=m/(V_{2}-V_{1}), round the result correctly, and explain why writing extra digits is misleading.

Solution

Step 1. Volume — subtraction first. V=V2−V1=58.5−50.0=8.5V=V_{2}-V_{1}=58.5-50.0=8.5 mL. By the addition and subtraction rule we take the smallest number of decimal places (one), so the volume has 2 significant figures. Step 2. Division. ρ=24.31/8.5=2.8600…\rho=24.31/8.5=2.8600\ldots g/mL. By the multiplication and division rule the limiting input is the volume with two significant figures, so ρ=2.9\rho=2.9 g/mL. Step 3. Explanation. Writing ρ=2.8600\rho=2.8600 g/mL would claim fifth-digit precision that does not exist: the volume was measured with only two significant figures, and it limits the precision of the result. Extra digits give a false impression of how reliable the data are.

Practice

Text

Measurement and rounding (safe, at home). Take a book and a ruler with a scale division of 11 mm. Measure the length and width of the book three times, shifting the ruler slightly each time, and record the results to 0.10.1 cm. For each pair of measurements compute the area, round it by the significant-figure rules, and arrange everything in a table: measurement, number of significant figures, area before rounding, area after rounding. Then answer in writing: how many significant figures does each measurement give, and which one limits the precision of the area? If no ruler or object is available, carry out the same calculation in an interactive measurement simulation (virtual ruler or vernier caliper): it is safe and needs no instruments. Do not use open flames, sharp tools, or energised electrical circuits.

Visual reference

Purpose

To show which digits in a recorded value count as significant and to recall which rounding rule applies to each operation.

Representation

Sketch: the value 0.0045070.004507 with labels and arrows — leading zeros marked as not significant, digits 44, 55, 00, 77 marked as significant. Next to it a flow chart with two branches: "multiplication/division →\rightarrow smallest number of significant figures" and "addition/subtraction →\rightarrow smallest number of decimal places", with the rounding examples 51.87→5251.87\rightarrow 52 and 12.55→12.612.55\rightarrow 12.6 below.

Real-world examples

A 100 m sprint: division and surplus digits

Scenario

At a school competition the distance was measured with a tape: s=100.00 ms = 100.00\ \text{m}. The electronic timer showed t=12.34 st = 12.34\ \text{s}. The calculator gives v=100.00/12.34=8.103726… m/sv = 100.00 / 12.34 = 8.103726\ldots\ \text{m/s}. The official result is written as v=8.10 m/sv = 8.10\ \text{m/s}, although the calculator screen shows many more digits.

Connection

This is the division rule: in multiplication and division the result keeps as many significant figures as the least precise input. The time 12.34 s12.34\ \text{s} has four, the distance 100.00 m100.00\ \text{m} has five, so the answer keeps four: 8.104 m/s8.104\ \text{m/s}. Writing 8.1037 m/s8.1037\ \text{m/s} would credit the timer with a precision of 0.0001 s0.0001\ \text{s} that it does not have.

Kitchen scales: the trailing zeros

Scenario

A digital kitchen scale has a scale division of 0.001 kg0.001\ \text{kg}. Flour for dough is weighed out and the display reads 0.500 kg0.500\ \text{kg}. The same value written as 0.5 kg0.5\ \text{kg} implies a different scale with a division of 0.1 kg0.1\ \text{kg}, while 0.5000 kg0.5000\ \text{kg} would require a scale with a division of 0.0001 kg0.0001\ \text{kg}.

Connection

Zeros after the decimal point at the end of a number are significant: 0.500 kg0.500\ \text{kg} states that the mass lies between 0.4995 kg0.4995\ \text{kg} and 0.5005 kg0.5005\ \text{kg}, that is, it carries three significant figures. In this way the record of a result ties the number of digits to the scale division of the instrument and to the real uncertainty of the weighing.

Weather: subtracting temperatures and decimal places

Scenario

In the morning the outdoor thermometer read t1=−3.4 °Ct_1 = -3.4\ \text{°C}, in the afternoon t2=+5.2 °Ct_2 = +5.2\ \text{°C}. The warming during the day is Δt=t2−t1=5.2−(−3.4)=8.6 °C\Delta t = t_2 - t_1 = 5.2 - (-3.4) = 8.6\ \text{°C}. Writing 8.60 °C8.60\ \text{°C} would be wrong, even though both readings carry two significant figures each.

Connection

This is the addition and subtraction rule: the result keeps not the number of significant figures but the number of decimal places — the smallest among the terms. Both readings have one digit after the decimal point, so the difference has one as well: 8.6 °C8.6\ \text{°C}. The added zero in 8.608.60 would claim a thermometer precision of 0.01 °C0.01\ \text{°C}.