humidity and psychrometric measurement

Learning objectives

  • Outcome

    Given absolute humidity ρ\rho and saturated vapour density ρ0\rho_0, computes relative humidity φ=ρρ0⋅100%\varphi=\frac{\rho}{\rho_0}\cdot100\% to within 1 %.

  • Outcome

    Uses a saturated-vapour table to find the dew point of air with a given temperature tt and relative humidity φ\varphi.

  • Outcome

    From dry-bulb t1t_1 and wet-bulb t2t_2 readings, computes the vapour partial pressure p=p2−A patm Δtp=p_2-A\,p_{\text{atm}}\,\Delta t and then the relative humidity.

  • Outcome

    Estimates the mass of water condensed when air is cooled below the dew point, using m=(ρ−ρ0′)Vm=(\rho-\rho_0')V.

Understand the idea

Humidity and Psychrometric Measurement

Text

Absolute humidity is the density ρ\rho of water vapour in air at a given temperature, while relative humidity shows how close that vapour is to saturation:

φ=ρρ0⋅100%=pp0⋅100%,\varphi=\frac{\rho}{\rho_0}\cdot100\%=\frac{p}{p_0}\cdot100\%,

where ρ0\rho_0 and p0p_0 are the density and partial pressure of saturated vapour at the same temperature. Replacing the density ratio by the pressure ratio is valid because water vapour in air obeys the ideal-gas equation of state p=ρMRTp=\frac{\rho}{M}RT, so at constant temperature p∝ρp\propto\rho. The dew point is the temperature at which the vapour becomes saturated at constant pressure; cooling below the dew point condenses the excess vapour. Psychrometric measurement relies on evaporation: the wet thermometer cools more the drier the air is, and from the difference Δt=t1−t2\Delta t=t_1-t_2 the vapour partial pressure is found with the psychrometric formula p=p2−A patm Δtp=p_2-A\,p_{\text{atm}}\,\Delta t, where p2p_2 is the saturated vapour pressure at the wet-bulb temperature, patmp_{\text{atm}} is atmospheric pressure, and A≈6.6×10−4 K−1A\approx6.6\times10^{-4}\ \text{K}^{-1} for an aspiration psychrometer.

Worked examples

Direct

Problem

At 20 °C the saturated water-vapour density is 17.3 g/m³. The absolute humidity of the air is 10.4 g/m³. Find the relative humidity.

Solution

Apply the definition of relative humidity:

φ=ρρ0⋅100%=10.417.3⋅100%≈60%.\varphi=\frac{\rho}{\rho_0}\cdot100\%=\frac{10.4}{17.3}\cdot100\%\approx60\%.

Answer: φ≈60%\varphi\approx60\%. The vapour is far from saturation, so no condensation occurs.

Application

Problem

A psychrometer reads t1=22t_1=22 °C (dry bulb) and t2=16t_2=16 °C (wet bulb). Atmospheric pressure is 101.3 kPa. The saturated vapour pressure is 1.82 kPa at 16 °C and 2.64 kPa at 22 °C. Find the relative humidity.

Solution

The depression is Δt=t1−t2=22−16=6\Delta t=t_1-t_2=22-16=6 °C. The psychrometric formula gives the vapour partial pressure:

p=p2−A patm Δt=1.82−6.6×10−4⋅101.3⋅6≈1.82−0.40=1.42 kPa.p=p_2-A\,p_{\text{atm}}\,\Delta t=1.82-6.6\times10^{-4}\cdot101.3\cdot6\approx1.82-0.40=1.42\ \text{kPa}.

Relative humidity:

φ=pp1sat⋅100%=1.422.64⋅100%≈54%.\varphi=\frac{p}{p_1^{\text{sat}}}\cdot100\%=\frac{1.42}{2.64}\cdot100\%\approx54\%.

Answer: φ≈54%\varphi\approx54\%.

Transfer

Problem

A room of volume 60 m³ is at 20 °C with relative humidity 60 %. The saturated vapour density is 17.3 g/m³ at 20 °C and 9.4 g/m³ at 10 °C. How much water condenses if the air is cooled to 10 °C?

Solution

First find the absolute humidity at 20 °C:

ρ=φρ0=0.60⋅17.3=10.38 g/m3.\rho=\varphi\rho_0=0.60\cdot17.3=10.38\ \text{g/m}^3.

At 10 °C the air can hold at most ρ0′=9.4\rho_0'=9.4 g/m³, so the excess condenses:

m=(ρ−ρ0′)V=(10.38−9.4)⋅60=0.98⋅60=58.8≈59 g.m=(\rho-\rho_0')V=(10.38-9.4)\cdot60=0.98\cdot60=58.8\approx59\ \text{g}.

Sanity check: the dew point lies between 10 °C and 20 °C, which agrees with condensation. Answer: m≈59m\approx59 g.

Practice

Text

Home psychrometer (safe independent measurement).

  1. Take two identical thermometers. Wrap the bulb of one in a piece of gauze or cambric moistened with room-temperature water — this is the wet-bulb thermometer.
  2. Fan air over the wet bulb (with a fan or a book) for 3–4 minutes until its reading stops changing, and read the dry-bulb thermometer at the same time. Record t1t_1 and t2t_2.
  3. Compute Δt=t1−t2\Delta t=t_1-t_2. From a table take p2p_2 at t2t_2 and p1satp_1^{\text{sat}} at t1t_1; then compute p=p2−A patm Δtp=p_2-A\,p_{\text{atm}}\,\Delta t and φ=pp1sat⋅100%\varphi=\frac{p}{p_1^{\text{sat}}}\cdot100\%.
  4. Repeat 5 times in different places in the room, compare with a household hygrometer, and explain the differences.
  5. In a spreadsheet, plot φ(Δt)\varphi(\Delta t) for t1=22t_1=22 °C, taking p2p_2 from the table.

Safety: do not heat thermometers, do not use an open flame, and do not break the instruments. If temperatures above 40 °C or below 0 °C, fog, frost, or other hazardous conditions are required, work only with a simulation or tabulated data.

Visual reference

Purpose

Show how the dew point and the dry-bulb and wet-bulb readings relate to the saturation-vapour-pressure curve, and how the temperature difference yields relative humidity.

Representation

Graph: temperature on the horizontal axis, saturated vapour pressure p0(T)p_0(T) on the vertical axis (an increasing curve). Three points are marked on the curve: AA — dry bulb t1t_1 (height p1satp_1^{\text{sat}}), BB — wet bulb t2t_2 (height p2p_2), CC — dew point tdt_d (height pp). A dashed horizontal line drawn from pp on the pressure axis meets the curve at the dew point; the segment between AA and BB on the temperature axis is labelled Δt\Delta t.

Real-world examples

A cold soda can on a hot day

Scenario

The air on a July afternoon is at T=30 ∘CT = 30\,^\circ\text{C} with relative humidity φ=70%\varphi = 70\%. The saturated vapour pressure at that temperature is psat(30 ∘C)=4.24 kPap_{\text{sat}}(30\,^\circ\text{C}) = 4.24\ \text{kPa}, so the partial pressure of the water vapour is e=0.70×4.24 kPa=2.97 kPae = 0.70 \times 4.24\ \text{kPa} = 2.97\ \text{kPa}. At 24 ∘C24\,^\circ\text{C} saturated vapour has the same pressure, so the dew point is 24 ∘C24\,^\circ\text{C}. The can is taken from the fridge at 4 ∘C4\,^\circ\text{C}: its surface is far colder than the dew point, water vapour condenses on it, and within a minute a film of drops appears.

Connection

Uses the psychrometric definitions: relative humidity φ=e/psat(T)\varphi = e/p_{\text{sat}}(T) compares the real vapour partial pressure with the saturated value at the same temperature, and the dew point is the temperature TdT_d at which e=psat(Td)e = p_{\text{sat}}(T_d). Any surface colder than TdT_d forces condensation.

Football training in humid heat

Scenario

A coach measures the air with a psychrometer: dry bulb T=30 ∘CT = 30\,^\circ\text{C}, wet bulb Tw=26 ∘CT_w = 26\,^\circ\text{C}, depression ΔT=4 ∘C\Delta T = 4\,^\circ\text{C}. With psat(26 ∘C)=3.36 kPap_{\text{sat}}(26\,^\circ\text{C}) = 3.36\ \text{kPa} and the psychrometric coefficient A=0.00068 K−1A = 0.00068\ \text{K}^{-1}, e=3.36−0.00068×101.3×4=3.08 kPae = 3.36 - 0.00068 \times 101.3 \times 4 = 3.08\ \text{kPa}. Since psat(30 ∘C)=4.24 kPap_{\text{sat}}(30\,^\circ\text{C}) = 4.24\ \text{kPa}, φ=3.08/4.24≈73%\varphi = 3.08/4.24 \approx 73\%. Sweat on the skin evaporates from a vapour-pressure deficit of only 4.24−3.08=1.16 kPa4.24 - 3.08 = 1.16\ \text{kPa}, so the players overheat faster than in dry air at the same 30 ∘C30\,^\circ\text{C}.

Connection

Uses the psychrometric measurement: the wet-bulb thermometer loses heat by evaporation, and the rate of that cooling is set by the vapour-pressure deficit psat(Tw)−ep_{\text{sat}}(T_w) - e; the pair of dry and wet readings gives φ\varphi, which controls evaporation from the skin.

Drying laundry in a kitchen

Scenario

In a kitchen the thermometer reads T=22 ∘CT = 22\,^\circ\text{C} and a hygrometer reads φ=60%\varphi = 60\%. From psat(22 ∘C)=2.64 kPap_{\text{sat}}(22\,^\circ\text{C}) = 2.64\ \text{kPa} the vapour partial pressure is e=0.60×2.64=1.59 kPae = 0.60 \times 2.64 = 1.59\ \text{kPa}, and the dew point is about 14 ∘C14\,^\circ\text{C}, because psat(14 ∘C)=1.60 kPap_{\text{sat}}(14\,^\circ\text{C}) = 1.60\ \text{kPa}. A 2 kg2\ \text{kg} load of wet clothes holds about 1 kg1\ \text{kg} of water; it leaves only while e<psate < p_{\text{sat}}, and the deficit here is 2.64−1.59=1.05 kPa2.64 - 1.59 = 1.05\ \text{kPa}. The single-glazed window cools to 10 ∘C10\,^\circ\text{C}, below the dew point, so drops of condensate run down the pane.

Connection

Uses the same two psychrometric quantities — relative humidity φ=e/psat(T)\varphi = e/p_{\text{sat}}(T) and the dew point — to decide both how fast water evaporates from the cloth and where it condenses on the cold glass.